17. TORQUE LIMIT FUNCTION
569
Positioning can be performed by butting against a mechanical stop while
applying a torque limit to the servo motor.
A torque limit can be set using three methods: parameter input, DI signal
input, and input from the PMC.
A torque limit set using any of these methods is valid in all modes (EDIT,
AUTO, JOG, and so forth).
With the torque control function, a torque limit can be set using three
methods:
1: Torque control based on parameter input
2: Torque control based on DI signal input
3: Torque control based on input from the PMC
See Table 17.1 for information about about which torque control
method is used.
A torque control method can be selected separately for the each axis.
Table 17.1 Torque Control Method Selection
Parameter
Torque limit enable signal (TRQnE)
(No.1855)
ON OFF
When set to 0 Torque control method
based on DI signal input
Torque control method
based on input from the
PMC
When set to a value other
than 0
Torque control method based on parameter input
n : 1 or 8
(2)(1)Position and alarm check when a torque limit is applied
An excessive position error and stop/move error can be ignored by
setting parameter TIP, TAL (No. 1803#0, #1) only when a torque limit
is applied.
(3)(1)Condition for activating this function
This function is activated when a value other than 0 is set in parameter
TRQLTn (No. 1855) (parameter for setting a torque limit).
NOTE
When 0 is specified in parameter No. 1855, the torque
control function based on parameter input is disabled.
(2) Applicable modes
This function can be used in all modes (EDIT, AUTO, and so forth).
(3) Parameter TRQLTn (No. 1855): parameter for setting a torque limit
Parameter No. 1855 sets a torque limit used for torque control.
This parameter can be rewritten with a G10 code even when a part
program is being executed.
17.1
OVERVIEW
Selecting a torque
control method
Torque Control Function
Based on Parameter