PMC Data Selection
Signal
EPMC
< G251#3 >
(Classification) Input signal
(Function) When this signal becomes logical "1", the CNC operates as
follows:
Select PMC data as the input/output data of “External I/O Device
Control”, when the parameter No.8761#0(EIB) is set to “1” and “the
enhanced way” is selected in “I/O Device External Control”.
Note)
1. The PMC address that can be output is as follows:
G0000-0255 F0000-0255 Y0000-0127
Y1000-1063 X0000-0127 X1000-1063
A0000-0024 R0000-2999 R9000-9199
T0000-0079 K0000-0019 C0000-0079
D0000-7999
2. The PMC data address that can be input is as follows:
R0000-2999 D0000-7999
3. When PMC data is output, it is necessary to set the External
Punch Start Data Number Signal (EDG00 – EDG15) in
accordance with the start address of data. Also, it is
necessary to set the External Punch Total Data Number
Signal (EDN00 – EDN15) in accordance with the total
number of PMC output data.
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
26/40
APPROV.
FANUC LTD