B–63173EN–1/01
12. DISPLAY/SET/EDIT
453
OP7 Feed hold on software operator’s panel
0 : Not performed
1 : Performed
#7
NS07202
#6
NS2
#5 #4 #3 #2 #1 #0
[Data type] Bit
NS2 0 : Uses the software operator’s panel general–purpose switches.
1 : Does not use the software operator’s panel general–purpose switches.
NS0 0 : Uses the software operator’s panel.
1 : Does not use the software operator’s panel.
7210 PLSKY1
[Data type] Bit
[Valid data range] 1, 2, 3, 4, 6, 7, 8, 9
This parameter specifies a key value used with the + direction key for the
first jog feed axis on the software operator’s panel.
7211 MNSKY1
[Data type] Bit
[Valid data range] 1, 2, 3, 4, 6, 7, 8, 9
This parameter specifies a key value used with the –direction key for the
first jog feed axis on the software operator’s panel.
7212 PLSKY2
[Data type] Bit
[Valid data range] 1, 2, 3, 4, 6, 7, 8, 9
This parameter specifies a key value used with the + direction key for the
second jog feed axis on the software operator’s panel.
7213 MNSKY2
[Data type] Bit
[Valid data range] 1, 2, 3, 4, 6, 7, 8, 9
This parameter specifies a key value used with the –direction key for the
second jog feed axis on the software operator’s panel.
7214 PLSKY3
[Data type] Bit
[Valid data range] 1, 2, 3, 4, 6, 7, 8, 9
This parameter specifies a key value used with the + direction key for the
third jog feed axis on the software operator’s panel.