In normal type high-speed position switch, when an axis is positioned
within the specified range, the signal is output to the Y address of the
built-in I/O.
As for the range to output a high-speed position switch, the maximum
values are given by the parameter No.8550 to No.8565 and the minimum
values are given by the parameter No.8580 to No.8595.
Note)
If the maximum value is less than the minimum value in a linear axis, the high-speed
position switch is never turned on because there is no effective range. If the
maximum value is less than the minimum value in a rotary axis, the range to output a
signal is the range including the point of 0 degree.
Normal type high speed position switch
Normal type high-speed position switch
Ran
e to out
ut si
nal
The maximum value:
No.8550-8565
The minimum value:
No.8580-8595
xis assignment:
No.8520-8535
n-th axis
(current position)
0 degree (= 360degree)
The maximum value: 45 degree
The minimum value: 315 degree)
Range to output a signal
(0 – 45 degree,
315 – 360 degree)
Rotary axis
(360deg./rev)
Ex)