#7 #6 #5 #4 #3 #2 #1 #0
6001
VFP
[Data type] Bit
VFP Change the output tape format of macro common variables.
0: Common variable is output in custom macro sentence format.
1: Common variable is output in the format similar to Power
Mate-A,B,C,E
Note)
The feature of each format is as follows:
[In case VFP=0]
The value of variable is output in the following <expression>.
#500=32000*65536/4194304
When macro variable is output by a soft key operation, select this
format.
The data output in this format can be restored to macro variable by
the following way.
1. Input the data as a program.
2. Execute the program in the automatic operation. Then the
input values are reflected to macro variables.
[In case VFP=1]
The value is output in the format “P# Macro variable number
Q#
Value of variable”
as follows:
P#500 Q00500.000
When macro variable is output by External I/O Device Control
Function, select this format.
The data output in this format can be restored to macro variable,
when the data are input by External I/O Device control Function.
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
39/40
APPROV.
FANUC LTD