12. DISPLAY/SET/EDIT
B–63173EN–1/01
452
#7 #6 #5 #4 #3 #2 #1 #0
OUT7F072 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
F073 ZRNO MD4O MD2O MD1O
F074
*SPOF075 KEYO DRNO MLKO SBKO BDTO
F076 ROV2O ROV1O MP2O MP1O
F077 RTO HS1DO HS1CO HS1BO HS1AO
*FV7OF078 *FV6O *FV5O *FV4O *FV3O *FV2O *FV1O *FV0O
*JV7OF079 *JV6O :JV5O *JV4O *JV3O *JV2O *JV1O *JV0O
*JV15OF080 *JV14O *JV13O *JV12O *JV11O *JV10O *JV9O *JV8O
–J4OF081 +J4O –J3O +J3O –J2O +J2O –J1O +J1O
#7 #6 #5 #4 #3 #2 #1 #0
7200 OP7 OP6 OP5 OP4 OP3 OP2 OP1
[Data type] Bit
OP1 Mode selection on software operator’s panel
0 : Not performed
1 : Performed
OP2 JOG feed axis select and manual rapid traverse buttons on software
operator’s panel
0 : Not performed
1 : Performed
OP3 Manual pulse generator’s axis select and manual pulse generator’s
magnification switches on software operator’s panel
0 : Not performed
1 : Performed
OP4 JOG feedrate override and rapid traverse override switches on software
operator’s panel
0 : Not performed
1 : Performed
OP5 Optional block skip, single block, machine lock, and dry run switches on
software operator’s panel
0 : Not performed
1 : Performed
OP6 Protect key on software operator’s panel
0 : Not performed
1 : Performed
Signal address
Parameter