B-63174EN/01-7
32/35EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate i - MODEL D/ H
OPRATOR’S MANUAL
THE FUNCTION OF DPL/MDI
TITLE
DRAW.NO. CUST.
SHEET
01
010913 New design
(DPL/MDI)
Classifi-
cation
Function KEY
SW
SETTING
PWE = 1
Mode Function
key
Operation
All memory clear Power ON -
<7>AND <9>
<PARAM>
Parameter/offset clear
Power ON -
Power Mate i –D: 1 path side of dual
paths system
<1>+<PARAM>
Power Mate i –D: 2 path side of dual
paths system
<2>+<PARAM>
<DELETE>
Program clear
Power ON -
Power Mate i –D: 1 path side of dual
paths system
<1>+< DELETE >
Power Mate i –D: 2 path side of dual
paths system
<2>+< DELETE >
Alarm clear - -
<CAN> or Power OFF/ON
Alarm P/S101 due to power-off
during editing
- -
<CAN> AND <ALARM>
Clear
PMC RAM clear Power ON -
<O> AND <X>
Reset OT alarm reset Power ON -
<P> AND <CAN>
Parameter input
- DGNOS /
PARAM
PARAM screen → <No.> →
Number → <INPUT> → Data →
<INPUT> → PWE=0 → <CAN>
PMC parameter input SETTING
DWE=1
- DGNOS /
PARAM
DGNOS screen → < PMC address>
Number → <INPUT> → Data→
<INPUT>
Pitch error compensation data
input
- DGNOS /
PARAM
Pitch error compensation data input
screen → <No.> → Data umber →
<INPUT> → Data → <INPUT>
Setting data input - VAR
Setting data screen →
Cursor movement → Data→ <INPUT>
Offset data input
- VAR
Offset data screen → <No.> →
Data Number → <INPUT> →
Data → <INPUT>
Registra-
tion from
MDI
Macro variable data input
- VAR
Macro variable screen → <No.> →
Data Number → <INPUT> →
Data → <INPUT>
Please add the following description before the " WARNING" of " H, LIST OF OPERATION" in