B–63173EN–1/01
3. MANUAL OPERATION
153
If the jog feed (JOG) mode is selected, and a return signal (RTN1n,
RTN2n, or RTN3n) is set to 1, rapid traverse occurs to the reference
position specified by the return signal. If the signal becomes 0 during
rapid traverse, axis movement is decelerated to a stop. When the reference
position is reached, axis movement is stopped completely, and the
reference position return completion output signal (ZPn, ZP2n, or ZP3n)
signal is set to 1.
Before starting to use this function, it is necessary to set up the origin; a
reference position return should be made previously.
[Classification] Input signal
[Function] This signal enables the jog feed (JOG) mode to select an axis to be
returned to a reference position, and also select the corresponding
reference position number (1 to 3).
1 Return signal for 1st axis
2 Return signal for 2nd axis
: :
: :
1 1st reference position
2 2nd reference position
3 3rd reference position
R T N 1 1
[Operation] If the signal becomes 1, the control unit behaves as follows:
If jog feed is possible, rapid traverse is performed for the selected axis
until the selected reference position is reached. When the reference
position is reached, the corresponding reference position return
completion signal becomes 1.
3.4
RETURN SIGNAL
General
Signal
Return Signal
RTN1n <G206>
RTN2n <G207>
RTN3n <G208>