B–63173EN–1/01
4. REFERENCE POSITION ESTABLISHMENT
199
CAUTION
1 In the following cases, the machine moves to the reference position without establishing the
reference position as described above:
S Axial movement is performed in ZRN mode when the reference position has already been
established.
S Automatic reference position return (G28) is specified when the reference position has
already been established.
2 Axial movement is continued until three or four reference marks are detected. If the
establishment of the reference position is started at a point near the end of the scale, therefore,
axial movement does not stop until overtravel occurs. Start establishing the reference position
at a point sufficiently distant from the end of the scale.
Scale end Reference marks
Start point (not recommended)
Start point (recommended)
Caution