8. AUXILIARY FUNCTION
B–63173EN–1/01
312
[Classification] Input signal
[Function] Reports that the execution of a spindle speed function using the
high–speed M/S/T interface is completed.
[Operation] For the operation and procedure of the control unit when this signal turns
to “1” and “0”, see the description of “Basic procedure
” above.
[Classification] Input signal
[Function] Reports that the execution of a tool function using the high–speed M/S/T
interface is completed.
[Operation] For the operation and procedure of the control unit when this signal turns
to “1” and “0”, see the description of “Basic procedure
” above.
[Classification] Input signal
[Function] Indicate that when the high–speed interface is used for multiple M com-
mands per block, the second to 3rd M functions have been completed.
[Operation] See “Basic procedure” for how the control unit operates and what it per-
forms when the signal turns to “1” and “0”.
#7
G004
#6 #5
MFIN3
#4
MFIN2
#3 #2 #1 #0
G005 TFIN SFIN MFIN
#7
MHI3001
#6 #5 #4 #3 #2 #1 #0
MHI Exchange of strobe and completion signals for the M, S, and T codes
0 : Normal
1 : High–speed
Spindle function
completion signal
SFIN <G005#2>
Tool function completion
signal TFIN <G005#3>
2nd, 3rd M function
completion signals
MFIN2, MFIN3
<G004#4, #5>
Signal address
Parameter