B–63173EN–1/01
1. AXIS CONTROL
48
D AXIS controlled axis number. . . .
This item is the placing of the NC controlled axis.
D NAME controlled axis name. . .
D AMP type of the amplifier connected to each axis. . . .
D M1 connector number for pulse module 1. . . . . .
This item is the number of the connector for pulse module 1,
specified in parameter No. 1931.
D M2 connector number for pulse module 2. . . . . .
This item is the number of the connector for pulse module 2,
specified in parameter No. 1932.
D 1–DSP
This item is the value specified in bit 0 (parameter 1DSP) of
parameter No. 1904. It is 1 for an axis that exclusively uses a DSP,
which is usually shared by two axes.
D CS
Not used.
D TNDM
This item is the number specified in parameter No. 1934.
Consecutive odd and even numbers are displayed for the master
and slave axes for tandem control.
(3)Amplifier maintenance screen
The amplifier maintenance screen displays maintenance information
for servo amplifiers. This screen consists of the following two pages,
either of which can be selected by pressing the
PAGE
or
PAGE
key.
AMPLIFIER MAINTENANCE O1000 N00001
AXIS NAME AMP SERIES UNIT AXES CUR.
1 X A1–L α SVM–HV 2 40AL
2 Y A1–M α SVM 2 12A
3 Z A2–L β SVM 1 40A
4 A A3–L α SVM 2 20A
5 B A3–M α SVM 2 40A
6 C A4–L α SVU 1 240A
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][ ]