EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i - MODEL D/H
Status display for PMC axis control
B-63173EN-1/01-44
SHEET
6/ 8
APPROV.
FANUC LTD
050727 01
New design
(2) Display the
waiting buffer (command value) for PMC axis control
Display items
· COMMAND Axis control command signals EC0g to EC6g in waiting
buffer are displayed.
· SUB CMD Sub-command number in waiting buffer is displayed.
· FEEDRATE SIGNAL Axis control feedrate signals EIF0g to EIF15g in
waiting buffer are displayed.
· DATA SIGNAL Axis control data signals EID0g to EID31g in waiting
buffer are displayed.
· SUB CMD DATA1(4) 4 byte data that is designated in offset +4 of
sub-command in waiting buffer are displayed.
· SUB CMD DATA2(4) 4 byte data that is designated in offset +8 of
sub-command in waiting buffer are displayed.
· SUB CMD DATA3(4) 4 byte data that is designated in offset +12 of
sub-command in waiting buffer are displayed.
· SUB CMD DATA4(4) 4 byte data that is designated in offset +16 of
sub-command in waiting buffer are displayed.
· SUB CMD DATA5(4) 4 byte data that is designated in offset +20 of
sub-command in waiting buffer are displayed.
· SUB CMD DATA6(4) 4 byte data that is designated in offset +24 of
sub-command in waiting buffer are displayed.
PMC AXIS CONTROL O0001 N00001
(WAITING BUF) X AXIS Y AXIS
COMMAND/SUB CMD 1/--- 34/ 8
FEEDRATE SIGNAL 5535 68
DATA SIGNAL 10000 120
SUB CMD DATA1(4) --- 1
SUB CMD DATA2(4) --- 250
SUB CMD DATA3(4) --- 10000
SUB CMD DATA4(4) --- 150
SUB CMD DATA5(4) --- ---
SUB CMD DATA6(4) --- ---
MDI **** *** *** 12:00:00
[ DEC ][ HEX ][AXIS-L][AXIS-R][ ]