B–63173EN–1/01
2. PREPARATIONS FOR OPERATION
102
This signal disables machine movement along axes. When this signal is
input during movement along axes, the tool movement is decelerated,
then stopped.
[Classification] Input signal
[Function] This signal is used to inhibit the machine from moving, and is effective
regardless of the selected mode.
[Operation] When the *IT or *RILK signal is “0”, the axis movement is decelerated
and stopped. In automatic operation, blocks containing M, S, or T mode
commands are executed consecutively until a block containing an axis
move command is encountered; the system then stops and is placed into
the automatic operation mode (cycle start lamp signal STL is “1”, feed
hold lamp signal SPL is “0”). When the *IT or *RILK signal turns to “1”,
operation resumes (Figs. 2.5(a), (b)).
*IT
Command read
Axis move
Fig. 2.5 (a) Block containing only axis move command
(manual and automatic operation)
MF/SF/TF
FIN
*IT
Command read
Fig. 2.5 (b) Block containing auxiliary functions only
(automatic operation)
2.5
INTERLOCK
General
Signal
All axes Interlock signal
*IT<G008#0>
*RILK<X0000#6> or
<X1000#6>