(b) Outputting PMC data
① Turn the PMC data selection signal “EPMC” to “1” and turn the
other selection signals to “0”.
② Specify an input channel by the external I/O device control channel
selection signal, “EXIO1 and EXIO2”. When RS-232-C is selected,
set the value 0 or 1 to the parameter No.20. Set the parameters of
reader/puncher interface corresponding to the selected RS-232-C
channel.
③ Specify the output file name by the external I/O device control file
name selection signal, “FLN00-FLN15”.
④ Set the start number of PMC data to be output by setting the
external punch start signal, “EDG00 to EDG15”, as follows.
Start number Value of EDG00-EDG15
G0000 to 0255 21000 + start number of G
F0000 to 0255 23000 + start number of F
Y0000 to 0127 25000 + start number of Y
Y1000 to 1063 25000 + start number of Y
X0000 to 0127 27000 + start number of X
X1000 to 1063 27000 + start number of X
A0000 to 0024 29000 + start number of A
R0000 to 2999 30000 + start number of R
R9000 to 9199 30000 + start number of R
T0000 to 0079 40000 + start number of T
K0000 to 0019 41000 + start number of K
C0000 to 0079 42000 + start number of C
D0000 to 7999 43000 + start number of D
⑤ Set the number of PMC data to be output by setting the external
punch total number signal, “EDN00 to EDN15”.
⑥ After the mode other than MDI mode is selected, output of PMC is
started by turning on the external I/O device control external punch
start signal, “EXWT”.
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
12/40
APPROV.
FANUC LTD