B–63173EN–1/01
1. AXIS CONTROL
53
D For those axes for which an odd number is set for parameter No. 1023,
the fast type must be used.
D For those axes for which an even number is set for parameter No.
1023, only the slow type is usable; this bit must be set to 1.
Controlled
axis
number
X (Fast)
A (Slow)
Y (Fast)
Z (Slow)
B (Fast)
C (Slow)
Two–axis
amplifier
Single–axis
amplifier
Single–axis
amplifier
Two–axis
amplifier
1X1F
2Y3F
3Z4S
4A2S
5B5F
6C6S
Program
axis name
(No. 1020)
Servo axis
number
(No. 1023)
Interface
type
(fast/slow)
CNC
PM1 Specifies whether the first pulse module is to be used.
0 : Not used.
1 : Used.
PM2 Specifies whether the second pulse module is to be used.
0 : Not used.
1 : Used.
If automatic setting is set as the FSSB setting mode (bit 0 of parameter
No. 1902 = 0), this parameter is set automatically when data is entered
using the FSSB setting screen. For manual setting 2 (bit 0 of parameter
No. 1902 = 1), the user must set this parameter. When using a pulse
module, a connection number must be specified separately (parameter
Nos. 1936 and 1937).