(Data type) Bit
E01~E16
Set whether each high-speed position switch can be used or not. When the
position switch is not used, the status of corresponding signal is always 0.
The two-digit number part in the parameter name corresponds to the
position switch number.
Ex) E01: Setting for the first high-speed position switch
E16: Setting for the sixteenth high-speed position switch
High-speed position switch is
0: effective
1: not effective. (The status of high-speed position switch is always 0.)
Note) The signal that is set not to be effective by this parameter can not be used for
the purpose other than a high-speed position switch.
(Data type) Bit
No. #7 #6 #5 #4 #3 #2 #1 #0
8500
8505 D16 D15 D14 D13 D12 D11 D10 D09
No. #7 #6 #5 #4 #3 #2 #1 #0
8504 D08 D07 D06 D05 D04 D03 D02 D01
E08 E07 E06 E05 E04 E03 E02 E01
8501 E16 E15 E14 E13 E12 E11 E10 E09
D01~D16
Set the output method of each high-speed position switch. The two-digit
number part in the parameter name corresponds to the position switch
number.
Ex) D01: Setting for the first high-speed position switch
DE16: Setting for the sixteenth high-speed position switch
The method of high-speed position switch is
0: normal type. (Signal output condition is judged by an axis position.)
1: judging a passing direction type. (Signal output condition is judged
by an axis position and moving direction.)
Note) When this parameter is set, the power must be turned off before operation is
continued.