B–63173EN–1/01
1. AXIS CONTROL
63
#7 #6 #5 #4 #3 #2 #1 #0
1008 RRLx RABx ROAx
NOTE
After setting this parameter, turn the power off then on again
so that the setting will take effect.
[Data type] Bit axis
ROAx The roll–over function of a rotation axis is
0 : Invalid
1 : Valid
NOTE
ROAx specifies the function only for a rotation axis (for
which ROTx, #0 of parameter No. 1006, is set to 1)
RABx In the absolute commands, the axis rotates in the direction
0 : In which the distance to the target is shorter.
1 : Specified by the sign of command value.
NOTE
RABx is valid only when ROAx is 1.
RRLx Relative coordinates are
0 : Not rounded by the amount of the shift per one rotation
1 : Rounded by the amount of the shift per one rotation
NOTE
1 RRLx is valid only when ROAx is 1.
2 Assign the amount of the shift per one rotation in parameter
No. 1260.
1260 Move amount per rotation of rotary axis
NOTE
When this parameter is changed, turn off the power before
continuing operation.
[Data type] Two–word axis
Increment system IS–A IS–B IS–C Unit
Unit of data 0.01 0.001 0.0001 deg
Standard setting
value
36000 360000 3600000
[Valid data range] 1000 to 9999999
Set move amount per rotation of rotation axis.
[Unit of data]