Note) If this parameter is set, the power must be turned off before operation is
continued.
Example to set the parameter No.8516 and No.8517)
- In case the parameter No.8516=10 and No.8517=1000,
HPS01 --- the first high-speed position switch signal
(Warning)
1. When the high-speed position switch is used in both paths of Power Mate i-D dual
path control, the Y address for each path must be set different.
Ex) In case 4 points are assigned to the first path and 4 points are assigned to
the second path
(Right setting)
Parameter for the first path No.8516=4
No.8516=1000 (Y1000#0 to #3 are used)
Parameter for the second path No.8516=4
No.8516=1001 (Y1001#0 to #3 are used.)
(Wrong setting)
Parameter for the first path No.8516=4
No.8516=1000 (Y1000#0 to #3 are used)
Parameter for the second path No.8516=4
No.8516=1000 <--(Y1000#4 to #7 are used) is not
allowed.
HPS10 HPS9
Y1001
#7 #6 #5 #4 #3 #2 #1 #0
Y1000
HPS08 HPS07 HPS06 HPS05 HPS04 HPS03 HPS02 HPS01
2. The Y address that is accessed by the PMC ladder must not be used for the
high-speed position switch. If such Y address is used by mistake, there is a
possibility that the machine performs unexpected motion.
HPS02 --- the second high-speed position switch signal
: :
HPS10 --- the tenth high-speed position switch signal
Though Y1000#2 to #7 are not used in above case, these bits cannot be used for the
purpose other than the high-speed position switch. Y1002 can be used for the purpose
other than the high-speed position switch.
Ed
Page
18 / 26
Date Sign
Contents
FANUC Power Mate i-MODEL D/H
High Speed Position Switch
specifications
B-63173EN-1/01-31
TITLE
DRAWING