(Data type) 2-word
(Unit of data):
(Valid data range): -99999999 to 99999999
・Normal type
Specify the minimum value of the range to output the high-speed
position switch (in machine absolute coordinate value). If the
maximum value is less than the minimum value in a linear axis, the
high-speed position switch is not effective because there is no valid
range. If the maximum value is less than the minimum value in a
rotation axis, the signal is output in the range including the point of
0 degree.
・Judging a passing direction type
Specify the point to turn off the high-speed position switch signal (in
machine absolute coordinate). When an axis passed by this point in
the direction given by the parameter No.8512 and No.8513, the
high-speed position switch is changed.
(Warning)
This parameter has two different meaning, such as the minimum value of the
range to output the signal in case of normal type and the point to turn off the
signal in case of judging a passing direction type. So be careful to set this
parameter not to mistake types.
Least input increment IS-A IS-B IS-C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
Ed