B–63173EN–1/01
1. AXIS CONTROL
66
NOTE
If the synchronization error check function is not used, set
parameter 8314 to 0.
If the agreement between the positions of the master and slave axes is lost
when the system power is turned off, the function compensates for the
difference between them. After performing a follow–up at power on, the
function sends compensation pulses to the slave axis to adjust its position
such that it agrees with that of the master axis. This function is enabled
only when the slave axis of synchronization control supports the
absolute–position detection function.
This function, however, cannot be used for rotation axes.
WARNING
1 The synchronization compensation function is enabled
after reference position returns have been performed. The
function is not executed if the parameter is set before
reference position returns are performed.
2 The synchronization compensation function is not executed
when the servo alarm is eliminated.
CAUTION
The synchronization deviation is processed as a position
error on the slave axis while at rest. The position error is
displayed as diagnostic data 300, in the same units as used
to detect the error. If the error exceeds the value set in
parameter 8315 (if only one master/slave axis pair is in
sync) or 8325 (if more than one master/slave axis pair is in
sync), servo alarm 410 is triggered. The alarm can be
cleared by pressing the reset key. As the position error for
the slave axis remains even after the alarm is cleared,
however, the positions must be adjusted.
NOTE
1 To use the synchronization compensation function, set the
SOF bit, bit 7 of parameter 8301 (if only one master/slave
axis pair is in sync) or SOFx bit, bit 7 of parameter 8303 (if
more than one master/slave axis pair is in sync), to 1.
2 The synchronization compensation function is also enabled
when emergency stop is canceled.
To use simple synchronous control, it is necessary to perform reference
position return for the master and slave axes. This function causes the
CNC to automatically perform reference position return (grid position)
for both the master and slave axes in simple synchronization.
[Operating procedure] This procedure can be applied only when one master/slave axis pair is in
sync, and when bit 0 (ATE) of parameter No. 8302 is set to 1. If more than
D Synchronization
compensation function
D Automatic setting of grid
positioning