B–63173EN–1/01
2. PREPARATIONS FOR OPERATION
137
This signal indicates whether the current amount of positional deviation
has exceeded the corresponding check value specified in parameter No.
1872.
This signal indicates that the current amount of positional deviation has
exceeded the corresponding check value specified in parameter No. 1872.
[Classification] Output signal
[Function] This signal indicates that the current amount of positional deviation has
exceeded the corresponding check value specified in parameter No. 1872.
1 Servo position deviation monitor signal of 1st axis
2 Servo position deviation monitor signal of 2nd axis
: :
: :
S V E R 1
[Output condition] The signal becomes 1 if:
– The current amount of positional deviation exceeds the corresponding
check value specified in parameter No. 1872.
The signal is 0 if:
– The current amount of positional deviation has not exceeded the
corresponding check value specified in parameter No. 1872.
#7
SVER8F222
#6
SVER7
#5
SVER6
#4
SVER5
#3
SVER4
#2
SVER3
#1
SVER2
#0
SVER1
1872 Servo positional deviation check value
[Data type] Doubleword axis
[Valid data range] 0 to 99999999
This parameter specifies a servo positional deviation check value. When
this value is exceeded, signals SVER1 to SVER8 are turned on.
2.13
SERVO POSITION
DEVIATION MONITOR
SIGNAL
General
Signal
Servo position deviation
monitor signal SVERn
<F222>
Signal address
Parameter