B–63173EN–1/01
1. AXIS CONTROL
58
Number DescriptionMessage
463 n AXIS : SEND SLAVE
DATA FAILED
The servo section failed to receive data
correctly because of an FSSB commu-
nication error.
464 n AXIS : WRITE ID DATA
FAILED
An attempt to write maintenance in-
formation to the amplifier maintenance
screen failed.
465 n AXIS : READ ID DATA
FAILED
An attempt to read the initial ID informa-
tion for the amplifier failed when the
power was switched on.
466 n AXIS : MOTOR/AMP
COMBINATION
The maximum current rating for the am-
plifier does not match that for the motor.
467 n AXIS : ILLEGAL SET-
TING OF AXIS
The servo function has not been en-
abled when an axis occupying a single
DSP is specified on the axis setting
screen.
Number Message Description
5134 FSSB : OPEN READY
TIME OUT
The FSSB did not become ready to
open during initialization.
5135 FSSB : ERROR MODE The FSSB entered an error mode.
5136 FSSB : NUMBER OF
AMPS IS SMALL
The number of amplifiers recognized
by the FSSB is insufficient, compared
with the number of controlled axes.
5137 FSSB : CONFIGURATION
ERROR
The FSSB detected a configuration er-
ror.
5138 FSSB : AXIS SETTING
NOT COMPLETE
Axis setting has not been performed in
automatic setting mode. Perform axis
setting using the FSSB setting screen.
5197 FSSB : OPEN TIME OUT The FSSB did not open when the CNC
had allowed the FSSB to open.
5198 FSSB : ID DATA NOT
READ
The initial ID information for the amplifi-
er cannot be read because of a failure
in the temporary assignment.
D P/S alarms