B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 107 -
1821 Reference counter size for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
Set a reference counter size.
As a reference counter size, specify a grid interval for reference
position return based on the grid method.
When a value less than 0 is set, the specification of 10000 is assumed.
When a linear scale with absolute address reference marks is used, set
the interval of mark 1.
1822 Value of the numerator of arbitrary command multiplier n/m
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 9999
Set the value of the numerator of the arbitrary command multiplier
n/m.
The arbitrary command multiplier option is required.
When a value other than 0 is set in parameter No. 1822 and No. 1823,
the setting of the arbitrary command multiplier n/m (n: No. 1822, m:
No. 1823) becomes valid.
1823 Value of the denominator of arbitrary command multiplier n/m
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 9999
Set the value of the denominator of the arbitrary command multiplier
n/m.
The arbitrary command multiplier option is required.
When a value other than 0 is set in parameter No. 1822 and No. 1823,
the setting of the arbitrary command multiplier n/m (n: No. 1822, m:
No. 1823) becomes valid.