4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 430 -
8580 Maximum value of the operation range of the first high-speed position switch
8581
Maximum value of the operation range of the second high-speed position
switch
:
8589
Maximum value of the operation range of the tenth high-speed position
switch
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the maximum value of the operation
range of each of the first to tenth high-speed position switches. If such
a setting that maximum value < minimum value is made, no operation
range exists, so that the high-speed position switch does not operate.
8590 Minimum value of the operation range of the first high-speed position switch
8591
Minimum value of the operation range of the second high-speed position
switch
:
8599
Minimum value of the operation range of the tenth high-speed position
switch
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the minimum value of the operation
range of each of the first to tenth high-speed position switches. If such
a setting that maximum value < minimum value is made, no operation
range exists, so that the high-speed position switch does not operate.