B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 509 -
4.73 PARAMETERS OF PERIODICAL SECONDARY PITCH
COMPENSATION
14985
Number of the periodical secondary pitch compensation position at the
extremely negative position for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1535
The compensation position set in this parameter is used as the
reference point for periodical secondary pitch error compensation.
This reference point is used as the compensation position at the
reference position.
The compensation at the reference point must be 0.
14986
Number of the periodical secondary pitch compensation position at the
extremely positive position for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1535
This parameter sets the periodical secondary pitch compensation
position at the extremely positive position for each axis.
14987
Interval between periodical secondary pitch compensation positions for
each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, deg (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 to interval between stored pitch error compensation positions
(parameter No. 3624)
This parameter sets the interval between periodical secondary pitch
compensation positions for each axis.