4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 484 -
13223 Start pot number of the first cartridge
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 1 to 9999
This parameter sets the start pot number to be used with the first
cartridge. Pot numbers starting with the value set in this parameter and
sequentially incremented by 1 are assigned to all data items.
13227 Number of data items in the second cartridge
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 1 to 64(Extended to 240 or 1000 by the addition of an option)
This parameter sets the number of data items used with the second
cartridge.
13228 Start pot number of the second cartridge
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 1to9999
This parameter sets the start pot number to be used with the second
cartridge. Pot numbers starting with the value set in this parameter and
sequentially incremented by 1 are assigned to all data items.
13232 Number of data items in the third cartridge
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 1 to 64(Extended to 240 or 1000 by the addition of an option)
This parameter sets the number of data items used with the third
cartridge.