4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 308 -
6031
Start number of common variables to be protected among the common
variables (#500 to #999)
6032
End number of common variables to be protected among the common
variables (#500 to #999)
[Input type] Parameter input
[Data type] Word path
[Valid data range] 500 to 999
Among the common variables (#500 to #999), the range of common
variables specified by this parameter can be protected (by setting their
attributes to read-only). If a write attempt (on the left side) is made, an
alarm is issued.
NOTE
Set 0 in both parameter No. 6031 and No. 6032 not
to protect common variables.
6033 M code that validates a custom macro interrupt
6034 M code that invalidates a custom macro interrupt
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 03 to 99999999 (excluding 30, 98 and 99)
These parameters can be used when MPR, #4 of parameter No.6003,
is 1. M96 is used as a valid M code and M97 is used as an invalid M
code when MPR is 0, irrespective of the state of this parameter.