B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 109 -
1828 Positioning deviation limit for each axis in movement
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Set the positioning deviation limit in movement for each axis.
If the positioning deviation exceeds the positioning deviation limit
during movement, a servo alarm (SV0411) is generated, and operation
is stopped immediately (as in emergency stop).
Generally, set the positioning deviation for rapid traverse plus some
margin in this parameter.
1829 Positioning deviation limit for each axis in the stopped state
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Set the positioning deviation limit in the stopped state for each axis.
If, in the stopped state, the positioning deviation exceeds the
positioning deviation limit set for stopped state, a servo alarm
(SV0410) is generated, and operation is stopped immediately (as in
emergency stop).
1830 Axis-by-axis positional deviation limit at servo-off time
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
This parameter is used to set a positional deviation limit at servo-off
time, on an axis-by-axis basis.
If the value specified with this parameter is exceeded at servo-off time,
a servo alarm is issued to cause an immediate stop (same as an
emergency stop). Usually, set the same value as a positional deviation
at stop time.