4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 136 -
4.16 PARAMETERS OF DISPLAY AND EDIT (1/2)
#7 #6 #5 #4 #3 #2 #1 #0
3101 KBF
[Input type] Parameter input
[Data type] Bit
# 1 KBF When the screen or mode is changed, the contents of the key-in buffer
are:
0: Cleared.
1: Not cleared.
#7 #6 #5 #4 #3 #2 #1 #0
DAC PPD MCN
3104
DAC DAL DRL PPD MCN
[Input type] Parameter input
[Data type] Bit path
# 0 MCN Machine position
0: Regardless of whether input is made in mm or inches, the
machine position is displayed in mm for millimeter machines, or
in inches for inch machines.
1: When input is made in mm, the machine position is displayed in
mm, and when input is made in inches, the machine position is
displayed in inches accordingly.
# 3 PPD Relative position display when a coordinate system is set
0: Not preset
1: Preset
NOTE
If any of the following is executed when PPD is set
to 1, the relative position display is preset to the
same value as the absolute position display:
(1) Manual reference position return
(2) Coordinate system setting based on G92 (G50
for G code system A on the lathe system)
(3) Workpiece coordinate system presetting based
on G92.1 (G50.3 for G code system A on the
lath system)
(4) When a T code for the lathe system is
specified, the relative position display is preset
to the same value as the absolute position
display.