B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 223 -
4971 Position gain multiplier (first stage)
4972 Position gain multiplier (second stage)
4973 Position gain multiplier (third stage)
4974 Position gain multiplier (fourth stage)
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 1 to 32767
Set a position gain multiplier for an analog spindle in spindle
positioning.
Position gain multiplier GC is obtained from the following equation:
LSPPLS
EPC
GC
××
×××
=
3602048000
PLS Number of pulses output from the position coder
(pulses/rev)
SP Number of gear teeth on the spindle side
PC Number of gear teeth on the position coder side
E Specified voltage (V) for turning the spindle motor at 1000 min
-1
L Angular displacement of the spindle (degrees) per spindle motor
rotation
Example: For the spindle motor and gear ratio given below, GC is
calculated as follows:
1100
36014096
2.213602048000
=
××
×××
=GC
PLS = 4096 pulse/rev
SP = 1
PC = 1
E = 2.2 V
L = 360 deg
NOTE
On the assumption that the spindle motor used
turns at 4500 min
-1
at 10 V, 2.2 V is required to turn
the spindle motor at 1000 min
-1