4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 380 -
NOTE
When a value other than the above is set, the axis
is not controlled by the PMC.
#7 #6 #5 #4 #3 #2 #1 #0
8011 XRT
[Input type] Parameter input
[Data type] Bit axis
# 0 XRT The axis that uses the group specified by parameter No. 8010 is:
0: Not controlled by the real time custom macro.
1: Controlled by the real time custom macro.
NOTE
1 This parameter is invalid for the axis for which 0 or a
value outside the range is set by parameter No.
8010
2 When multiple axes are assigned to the same group
by parameter No. 8010, these axes cannot be
controlled by the real time custom macro. When
multiple axes are assigned to the same group, be
sure to set this bit to 0.
3 When this parameter (No. 8011) is all 0s, the axis is
used for PMC axis control.