4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 118 -
#7 #6 #5 #4 #3 #2 #1 #0
1902 ASE FMD
[Input type] Parameter input
[Data type] Bit
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 FMD The FSSB setting mode is:
0: Automatic setting mode.
(When the relationship between an axis and amplifier is defined
on the FSSB setting screen, parameter Nos. 1023, 1905, 1936 to
1939, and 14340 to 14407 (plus parameter Nos. 14408 to 14425
and 14444 to 14459 if an additional axis board is attached) are
automatically set.
1: Manual setting 2 mode.
(Parameter Nos. 1023, 1905, 1936 to 1939 and 14340 to 14407
(plus parameter Nos. 14408 to 14425 and 14444 to 14459 if an
additional axis board is attached) are to be manually set.)
# 1 ASE When automatic setting mode is selected for FSSB setting (when the
FMD parameter (bit 0 of parameter No.1902) is set to 0), automatic
setting is:
0: Not completed.
1: Completed.
This bit is automatically set to 1 upon the completion of automatic
setting.
#7 #6 #5 #4 #3 #2 #1 #0
1905 PM2 PM1 PM4 PM3
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 1 PM3 The third separate detector interface unit is:
0: Not used.
1: Used.
# 2 PM4 The fourth separate detector interface unit is:
0: Not used.
1: Used.
# 6 PM1 The first separate detector interface unit is:
0: Not used.
1: Used.