B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 359 -
NOTE
A phase command is specified in address R, in
units of degrees. For control, the actual shift
amount is converted to a number of pulses
according to the conversion formula: 360 degrees
= 4096 pulses. This parameter switches the display
of a specified value to that of a converted value.
# 7 PST The polygon spindle stop signal *PLSST <Gn038.0>is:
0: Not used.
1: Used.
7610 Control axis number of tool rotation axis for polygon turning
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 1 to number of controlled axes
This parameter sets the control axis number of a rotation tool axis
used for polygon turning.
However, when a G51.2 command is executed by setting 0 in this
parameter, operation stops with the alarm (PS0314).
7620 Movement of tool rotation axis per revolution for polygon turning
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real path
[Unit of data] Degree
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B) )
(When the increment system is IS-B, 0.0 to +999999.999)
This parameter sets the movement of a tool rotation axis per
revolution.