This parameter is valid when bit 3 (DIA) of parameter No.1006
is set to 1 (A move command for each axis is based on diameter
specification.)
# 2 R10 When the parameter RPD (bit 0 of parameter No.8002) is set to 1, the
unit for specifying a rapid traverse rate for the PMC axis is:
0: 1 mm/min.
1: 10mm/min.
# 3 DRR For cutting feed per rotation in PMC axis control, the dry run function
is:
0: Disabled.
1: Enabled.
# 5 IFV When bit 2 (OVE) of parameter No. 8001 is set to 1 in PMC axis
control, the feedrate override signal *EFOVx and the override cancel
signal OVC are:
0: Used on a path-by-path basis. (The start groups (1st group, 5th
group, ... 33rd group, 37th group) of each path are used.)
1: Used on a group-by-group basis.
#7 #6 #5 #4 #3 #2 #1 #0
8006 EZR EFD MLS
[Input type] Parameter input
[Data type] Bit path
# 1 MLS When bit 0 of parameter No. 8001 is set to 1 (to disable the all axis
machine lock signal) in PMC axis control, axis-by-axis machine lock
is:
0: Disabled.
1: Enabled.
# 4 EFD When cutting feed (feed per minute) is used in PMC axis control, the
specification unit of feedrate data is:
0: Unchanged (1 times).
1: 100 times greater.
NOTE
When this parameter is set to 1, bit 3 of parameter
No. 8002 is invalid.
# 6 EZR In PMC axis control, bit 0 (ZRNx) of parameter No. 1005 is:
0: Invalid.
With a PMC controlled axis, the alarm (PS0224) is not issued.
1: Valid.
A reference position return state check is made on a PMC
controlled axis as with an NC axis according to the setting of bit
0 (ZRNx) of parameter No. 1005.
#7 #6 #5 #4 #3 #2 #1 #0