B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 171 -
#7 #6 #5 #4 #3 #2 #1 #0
3455 AXDx
[Input type] Parameter input
[Data type] Bit axis
# 0 AXDx If a decimal point is omitted for an axis address with which a decimal
point can be used, the value is determined:
0: In accordance with the least input increment. (Normal decimal
point input)
1: In millimeters, inches, or seconds. (calculator-type decimal point
input)
NOTE
This parameter specifies the calculator-type
decimal point input function for each axis.
For the same axis name, be sure to make the
same setting.
#7 #6 #5 #4 #3 #2 #1 #0
3457 SCF SYS MC1 MC2 LIB
[Input type] Parameter input
[Data type] Bit path
NOTE
1 The parameters LIB, MC2, MC1, and SYS are used
to set a search folder for the following
subprogram/macro calls:
・Subprogram call based on an M code
・Subprogram call based on a particular address
・Subprogram call based on a second auxiliary
function code
・Macro call based on a G code
・Macro call based on an M code
・Macro call based on a T code
・One-touch macro call
2 The parameter SCF is used to set whether to add a
search folder for the following subprogram/macro
calls:
・Subprogram call based on M98
・Figure copy based on G72.1/G72.2
・Macro call based on G65/G66/G66.1
・Macro interrupt based on M96
# 0 LIB The common program directory "//CNC_MEM/USER/LIBRARY/" of
the initial directories is:
0: Set as a search directory.