4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 322 -
# 6 MDC The measurement result of automatic tool length measurement (M
series) or automatic tool compensation (T series) is:
0: Added to the current offset.
1: Subtracted from the current offset.
#7 #6 #5 #4 #3 #2 #1 #0
6215 CSTx
[Input type] Parameter input
[Data type] Bit axis
# 0 CSTx On a Cs contour control axis, torque limit skip operation is:
0: Not performed.
1: Performed.
Torque limit skip operation is performed using the torque limit
command signal TLMH and the load detection signal LDT1 of the
serial spindle.
6220
Period during which skip signal input is ignored for the continuous
high-speed skip function and EGB axis skip function
[Input type] Parameter input
[Data type] Byte path
[Unit of data] 8msec
[Valid data range] 3 to 127(× 8msec)
This parameter specifies the period from when a skip signal is input to
when the next skip signal can be input for the continuous high-speed
skip function and EGB axis skip function. This parameter is used to
ignore chattering in skip signals.
If a value that falls outside the valid range is specified, the setting is
assumed to be 24 msec.
Signal ignoring period (parameter No. 6220)
Skip signal
This signal is ignored.
When high-speed skip signals are used and bit 5 (CSE) of parameter
No. 6201 is set to 1, signals are handled as follows:
Signal ignoring period (parameter No. 6220)
High-speed skip
signals
These signals
are ignored.