4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 170 -
3451
GQS
[Input type] Parameter input
[Data type] Bit path
# 0 GQS When threading is specified, the threading start angle shift function
(Q) is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
3452 EAP
[Input type] Parameter input
[Data type] Bit path
# 7 EAP When bit 0 (ADX) of parameter No. 3455 is set to 1, calculator-type
decimal point input at a macro calling argument address is:
0: Enabled.
1: Disabled.
NOTE
This parameter is valid when bit 0 (DPI) of
parameter No. 3401 is set to 0.
#7 #6 #5 #4 #3 #2 #1 #0
CRD
3453
[Input type] Setting input
[Data type] Bit path
# 0 CRD If the functions of chamfering or corner R and direct drawing
dimension programming are both enabled,
0: Chamfering or corner R is enabled.
1: Direct drawing dimension programming is enabled.