4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 424 -
8487 Angle at which smooth interpolation or Nano smoothing is turned off
[Input type] Setting input
[Data type] Real path
[Unit of data] Degree
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 to 90
This parameter sets the angle used to determine whether to apply
smooth interpolation or Nano smoothing.
At a point having a difference in angle greater than this setting,
smooth interpolation or Nano smoothing is turned off.
8490
Minimum travel distance of a block where smooth interpolation or Nano
smoothing is applied
[Input type] Setting input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a block length used to determine whether to apply
smooth interpolation or Nano smoothing.
If the line specified in a block is shorter than the value set in this
parameter, smooth interpolation or Nano smoothing is not applied to
that block.
8491 Maximum tolerance for a block where smooth interpolation is applied
[Input type] Setting input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a tolerance for deciding whether to perform
smooth interpolation.
For a block that has a tolerance greater than the value set in this
parameter, smooth interpolation is not performed. When 0 is set in this
parameter, a tolerance-based decision is not made.