4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 286 -
5464
Compensation for error on hypothetical axis of polar coordinate
interpolation
[Input type] Parameter input
[Data type] Byte path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(For IS-B, -999999.999 to +999999.999)
This parameter is used to set the error if the center of the rotation axis
on which polar coordinate interpolation is performed is not on the
X-axis.
If the setting of the parameter is "0", regular polar coordinate
interpolation is performed.