B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 317 -
4.33 PARAMETERS OF SKIP FUNCTION
#7 #6 #5 #4 #3 #2 #1 #0
6200 SKF SRE SLS HSS SK0 GSK
[Input type] Parameter input
[Data type] Bit path
# 0 GSK As a skip signal, the skip signal SKIPP is:
0: Invalid.
1: Valid.
# 1 SK0 This parameter specifies whether the skip signal is made valid under
the state of the skip signal SKIP and the multistage skip signals SKIP2
to SKIP8.
0: Skip signal is valid when these signals are 1.
1: Skip signal is valid when these signals are 0.
# 4 HSS
0: The skip function does not use high-speed skip signals while skip
signals are input. (The conventional skip signal is used.)
1: The step skip function uses high-speed skip signals while skip
signals are input.
# 5 SLS
0: The multi-step skip function does not use high-speed skip signals
while skip signals are input. (The conventional skip signal is
used.)
1: The multi-step skip function uses high-speed skip signals while
skip signals are input.
NOTE
The skip signals (SKIP and SKIP2 to SKIP8) are
valid regardless of the setting of this parameter.
They can also be disabled using bit 4 (IGX) of
parameter No. 6201.
# 6 SRE When a high-speed skip signal or high-speed measurement position
arrival signal is used:
0: The signal is assumed to be input on the rising edge (contact
open → close).
1: The signal is assumed to be input on the falling edge (contact
close → open).
# 7 SKF Dry run, override, and automatic acceleration/deceleration for G31
skip command
0: Disabled
1: Enabled