B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 337 -
4.39 PARAMETERS OF TOOL LIFE MANAGEMENT (1 OF 2)
#7 #6 #5 #4 #3 #2 #1 #0
6801 LVF
[Input type] Parameter input
[Data type] Bit path
# 2 LVF When the life of a tool is counted in terms of time with the tool
management function, the tool life count override signals *TLV0 to
*TLV9<G049#0 to G050#1> are:
0: Invalid.
1: Valid.
6811 Tool life count restart M code
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 255 (not including 01, 02, 30, 98, and 99)
When 0 is set, this parameter is ignored.
When an M code for tool life count restart is specified, the counting of
the life of the tool attached at the spindle position is started.
When the type for counting the number of use times is selected, the
target of life counting is switched to the tool attached at the spindle
position, and the life count is incremented by 1.
When the type for counting time is selected, the target of life counting
is switched to the tool attached at the spindle position, with no other
operations performed.
If the tool attached at the spindle position is not a tool under tool life
management, no operation is performed.