4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 216 -
4832
Master spindle of each slave spindle under spindle synchronization control
(spindle number common to the system)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte spindle
[Valid data range] 0 to Maximum number of controlled axes (common to the system)
When a spindle is set as a slave spindle in spindle synchronization
control on each spindle, set which spindle (master spindle) the slave
spindle is to be synchronized with.
NOTE
1 This parameter is valid if bit 4 (SSS) of parameter
No. 3704 is set to 1.
Bit 4 (SSS) of parameter No. 3704 must be set to 1
(to enable spindle synchronization based on
arbitrary spindles) for the path to which a slave
spindle belongs and for the path to which a master
spindle belongs.
2 The setting of a slave spindle as a master spindle
is invalid. Be sure to set 0 for a spindle that is to
function as a master spindle.
3 In this parameter, set a spindle number common to
the system. When this parameter is used,
parameter No. 4831 is set to 0.