B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 37 -
0983 Path control type of each path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 1
Set the path control type of each path.
The following two path control types are available:
T series (lathe system) : 0
M series (machining system) : 1
#7 #6 #5 #4 #3 #2 #1 #0
0984 LCP
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 LCP Set whether the path is a loader control path.
0: The path is not a loader control path.
1: The path is a loader control path.