4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 442 -
10300 Upper limit 2 of a tool offset number range No.01
to to
10303 Upper limit 2 of a tool offset number range No.04
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to maximum number of offset sets
Each of these parameters sets the upper limit of a tool offset number
range.
These parameters correspond to the tool offset lower/upper limits set
in parameter Nos. 10280 to 10295.
10304 Lower limit of workpiece zero point offsets No.01
to to
10309 Lower limit of workpiece zero point offsets No.06
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the lower limit of workpiece zero point
offset values.
10310 Upper limit of workpiece zero point offsets No.01
to to
10315 Upper limit of workpiece zero point offsets No.06
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the upper limit of workpiece zero point
offset values.