B–61863E/15
3. ADDRESS
PMC SEQUENCE PROGRAM
73
Table 3 Alphabetic Characters for PMC Address Number (12)
Control type
Address Type of signal Series 16i/18i/21i–B
PMC–SA1 PMC–SB7
X Input signal from machine tool to
PMC (MT→PMC)
X0 to X127 X0 to X127
X200 to X327*
1
X1000 to X1127*
2
Y Output signal from PMC to
machine tool (PM→CMT)
Y0 to Y127 Y0 to Y127
Y200 to Y327*
1
Y1000 to Y1127*
2
F Input signal from NC to PMC
(NC→PMC)
F0 to F255 F0 to F767*
3
F1000 to F1767*
4
F2000 to F2767*
4
F3000 to F3767*
5
G Output signal from PMC to NC
(PM→CNC)
G0 to G255 G0 to G767*
3
G1000 to G1767*
4
G2000 to G2767*
4
G3000 to G3767*
5
R Internal relay R0 to R999
R0 to R9099
R0 to R7999
R9000 to R9499*
6
E Extra relay*
7
– E0 to E7999
A Message request A0 to A24 A0 to A249
Message display state*
8
– A9000 to A9249
C Counter C0 to C79 C0 to C399
C5000 to C5199*
9
K Keep relay K0 to K19 K0 to K99
K900 to K919*
10
T Variable timer T0 to T79 T0 to T499
T9000 to T9499*
11
D Date table D0 to D1859 D0 to D9999
L Label number – L1 to L9999
P Subprogram number – P1 to P2000