B–61863E/15
8. WRITING, READING, AND COMPARING
SEQUENCE PROGRAMS AND
PMC PARAMETERS
PMC–NB6 MANIPULATION
803
Displayed error
message
Meaning and action
C LANGUAGE BOARD
IS NOT IMPLEMENTED
The C language board cannot be recognized.
Action: Check whether the C language board is
installed.
INTERNAL ERROR
(xxxxxxxxxx)
An error due to an internal factor occurred. Details
on the error are displayed in parentheses.
Action: Contact the FANUC service center, and
report the displayed message correctly.
D Error messages displayed during floppy cassettes, handy files or other
input/output devices I/O operation.
Displayed error
message
Meaning and action
BAD PMC PARAMETER
FORMAT
Specified file is not PMC parameter format.
Action: Specify file of PMC parameter format, or
check the contents of the file.
BAD HANDY FILE
FORMAT
Specified file is not handy file format.
Action: Specify file of handy file format, or check
the contents of the file.
UNKNOWN FILE
FORMAT
Can not recognize the format of specified file.
Action: Specify file of recognizable format such
as PMC parameter format, or check the
contents of the file.
FILE NAME OR FILE
NUMBER IS REQUIRED
Need file name or file number to identify file to
read, compare, or delete.
Action: Specify file name or file number for the
operation.
COMMUNICATION
TIMEOUT
Communication with the I/O device has been time-
out.
Action: Check the communication parameters
such as baud rate, and retry to communi-
cate.
I/O DEVICE IS NOT
ATTACHED OR IN
ERROR STATUS
Any I/O device is not connected, or some error has
occurred in it.
Action: Check the power of I/O device is ON.
Check the I/O device is connected.
Check the cable that connects I/O de-
vice with PMC is correct one.
If some error has occurred in I/O de-
vice, solve it.
RECEIVED BAD DATA:
CHECK THE
COMMUNICATION
PARAMETERS
Invalid data has been received.
Action: Check the PMC’s communication param-
eters such as baud rate match the ones of
I/O device.
RECEIVED DATA HAS
OVERRUN
Too many data have received at once.
Action: Check the communication parameters
about flow control.