5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
148
Table 5 (a) Types and Processing of Functional Instructions (6) Part 2
Model
Name
SUB
number
Processing Series 16i MODEL A/Series 18i MODEL A
number
PMC–SB5 PMC–SB6
ADDB 36 Binary addition f f
SUB 20 BCD subtraction f f
SUBB 37 Binary subtraction f f
MUL 21 BCD multiplication f f
MULB 38 Binary multiplication f f
DIV 22 BCD division f f
DIVB 39 Binary division f f
NUME 23 Definition of constant f f
NUMEB 40 Definition of binary constant f f
DISP 49 Message display (Caution) n n
DISPB 41 Extended message display f f
EXIN 42 External data input f f
AXCTL 53 PMC axis control f f
WINDR 51 Window data read f f
WINDW 52 Window data write f f
FNC9X 9X Arbitrary functional instruction
MMC3R 88 MMC3 window data read
MMC3W 89 MMC3 window data write
MMCWR 98 MMC2 window data read f f
MMCWW 99 MMC2 window data write f f
DIFU 57 Rising edge detection f f
DIFD 58 Falling edge detection f f
EOR 59 Exclusive OR f f
AND 60 Logical product f f
OR 61 Logical add f f
NOT 62 Logical negation f f
END 64 End of subprograms f f
CALL 65 Conditional subprogram call f f
CALLU 66 Unconditional subprogram call f f
SP 71 Subprogram f f
SPE 72 End of a subprogram f f
NOP 70 No operation f f
: Cannot be used f : Can be used n : Can be used (with some restrictions)