B–61863E/15
4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
PMC OPERATION (CRT/MDI)
475
The TIMER times of the functional instruction TMR(SUB 3) are set and
displayed on this screen.
01 T00 2016 11 T20 1000
02 T02 48 12 T22 8
03 T04 960 13 T24 0
04 T06 1008 14 T26 32
05 T08 0 15 T28 0
06 T10 0 16 T30 0
07 T12 96 17 T32 2000
08 T14 0 18 T34 0
09 T16 8 19 T36 8
10 T18 16 20 T38 10000
[TIMER ] [COUNTR ] [KEEPRL ] [ DATA ] [ ]
The addresses refered by sequence program
PMC PRM (TIMER) #001 MONIT RUN
Page No.(Change pages with the page keys.)
The TIMER No.s used by TIMER instruction
NO. ADDRESS DATA NO. ADDRESS DATA
TIMER times(See the following table.)
TIMER
No.s
Minimum
time
Maximum
time
1 to 8 48 (ms) 1572.8 (s)
9 to 40 or
8 (ms) 262.136 (s)
9 to 150
(*1)
*1 The usable numbers vary from one model to
another. For details, see Section 5.4 in Part I.
4.3
SETTING AND
DISPLAY SCREEN
4.3.1
Timer Screen (TIMER)