4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
B–61863E/15
PMC OPERATION (CRT/MDI)
488
Each setting parameter can be set when the respective conditions are
satisfied.
(a) Multi–language display function
D The PROGRAM ENABLE setting parameter is set to YES
(bit 1 of K17 or bit 1 of K900 is set to 1).
D The PMC model is SB6.
(b) OVERRIDE mode of the forced input/output function
D The PROGRAM ENABLE setting parameter is set to YES
(bit 1 of K17 or bit 1 of K900 is set to 1)
D The PMC model is SA5, SB5, or SB6.
D The editing function is provided.
(2) Setting operations
(a) Setting the Multi–language display function
Position the cursor to the each setting item with the arrow keys,
enter the desired data, then press the [INPUT] soft key.
PMC PRM (MESSAGE SHIFT) MONIT RUN
MESSAGE SHIFT VALUE = 0
MESSAGE SHIFT START ADDRESS = A0000.0
[INPUT] [ ] [ ] [ PREV ] [ NEXT ]
(i) Parameters
D MESSAGE SHIFT VALUE
Enter a desired message display request bit shift amount.
A value from 0 to 999 can be entered. The initially displayed
value is 0.
Entered data is maintained even after the power is turned off.
D MESSAGE SHIFT START ADDRESS
Enter a shift start bit address in the message display request
bit area.
An address A value can be entered. The initially displayed
value is A0.0.
Entered data is maintained even after the power is turned off.
NOTE
Data entered for MESSAGE SHIFT START ADDRESS is
valid only when a value other than 0 is entered for
MESSAGE SHIFT VALUE.