B–61863E/15
6. LADDER DIAGRAM MONITOR
AND EDITOR
PMC–NB6 MANIPULATION
699
NOTE
1 When [PMCLAD] soft key is pressed at first time after CNC
power cycle, Program List Viewer screen is displayed. Then
use [ZOOM] soft key to select subprogram to reach
LADDER Diagram Monitor screen, and the subprogram that
you have selected appears on the screen. Once you
choose subprogram, pressing [PMCLAD] soft key will
directly reach LADDER Diagram Monitor screen. Changing
LADDER program by I/O function will make the Program List
screen appear at [PMCLAD] soft key again. See ”Program
List screen” for more detail. (404A/04 does not have
Program List Viewer screen. LADDER Diagram Monitor
screen can be reached directly from PMC Main Menu
always.)
2 404A/04 can not display LADDER program that is protected
by Password function. To view a protected LADDER
program, you need FANUC LADDER–II, LADDER Editing
Package, or upgrade version to 404A/05 or later. 404A/05
or later will ask for password when necessary.
3 [EDIT] soft key in LADDER Diagram Monitor screen
appears only when Programmer function is enabled: to
enable Programmer function, set ”PROGRAMMER
ENABLE” to ”YES” at GENERAL screen of PMC Settings.
While Online Monitor function is active, you can not reach
LADDER Diagram Editor screen. To use LADDER Diagram
Editor function, you have to disable Online Monitor function
at PMC Setting screen: choose ”NOT USE”.